  tmc 60 series for mounting on 35 mm din rail overview the tmc 60 series provides supplemental overload and short-circuit protection. an interrupt capacity of 10 kaic at 480/277 v ac and dual ac/dc ratings make the series ideal for a wide range of applications. these din rail-mountable circuit breakers are available in one-, two-, and three-pole con gurations. an auxiliary contact in s- or h-function status output is also available. the tmc 60 series is ul recognized, csa approved, and carries the ce mark. typical application circuit protection for power supplies, ups, controller i/o points, relay/contactor coils, control circuits, appliances and motor circuits. technical data circuit breakers current range 0.5 to 63 amps ratings standard voltage number of poles ul 1077, csa 240/415 v ac 1 415 v ac 2, 3 48 v dc 1 110 v dc 2 (in series) trip characteristics c: 0.5-63a rated wire sizes - line/load rigid 35 mm?/ 2 awg min/max flexible 25 mm?/ 3 awg min/max torque 4.5 nm / 39.8 lb f -in vibration (per iec 77/16.3) 3 g (in x, y, z direction) endurance electrical @ v n , i n 10,000 mechanical 20,000 plastics rating per ul 94 v0 protection level ip 20 temperature operating -25? to +55?c (-13? to +131?f) storage -55? to +55?c (-67? to +131?f) configuration 1 pole 2 pole 3 pole weight 120 g 240 g 360 g thermal magnetic circuit breakers - ul 1077 ?008 phoenix contact l002487a:03.08 dimensions note: all measurements in millimeters
thermal magnetic circuit breakers part number description 0902014 tmc 61c 0,5a 0902027 tmc 61c 01a 0902030 tmc 61c 02a 0902043 tmc 61c 03a 0902056 tmc 61c 04a 0902069 tmc 61c 06a 0902072 tmc 61c 10a 0902085 tmc 61c 13a 0902098 tmc 61c 16a 0902108 tmc 61c 20a 0902111 tmc 61c 25a 0902124 tmc 61c 32a 0902137 tmc 61c 40a 0902140 tmc 61c 50a 0902153 tmc 61c 63a part number description 0902166 tmc 62c 0,5a 0902179 tmc 62c 01a 0902182 tmc 62c 02a 0902195 tmc 62c 03a 0902205 tmc 62c 04a 0902218 tmc 62c 06a 0902221 tmc 62c 10a 0902234 tmc 62c 13a 0902247 tmc 62c 16a 0902250 tmc 62c 20a 0902263 tmc 62c 25a 0902276 tmc 62c 32a 0902289 tmc 62c 40a 0902292 tmc 62c 50a 0902302 tmc 62c 63a part number description 0902315 tmc 63c 0,5a 0902328 tmc 63c 01a 0902331 tmc 63c 02a 0902344 tmc 63c 03a 0902357 tmc 63c 04a 0902360 tmc 63c 06a 0902373 tmc 63c 10a 0902386 tmc 63c 13a 0902399 tmc 63c 16a 0902409 tmc 63c 20a 0902412 tmc 63c 25a 0902425 tmc 63c 32a 0902438 tmc 63c 40a 0902441 tmc 63c 50a 0902454 tmc 63c 63a standard current ratings and typical internal resistance values one-pole two-pole three-pole typical time/current characteristics at 23 degrees celsius direct current - magnetic tripping currents are increased by 30 percent in dc circuits with the effect of shifting the magnetic trip range 30 percent to the right of alternating current (ac) trip curves.          


                   
 
  ! 

  
 "  

  
 "  
  

#$
#          


                   
 
  ! 

  
 "  

  
 "  
  #$
%# #
%           


                   
 
  ! 

  
 "  

  
 "  
  #$
# #
&
 the time/current characteristic curve depends on the prevailing ambient temperature. in order to eliminate nuisance tripping, multiply the circuit breaker current ratings by the derating factor shown at right. amps temperature ?c -20? -15? -10? -5? 0? +5? +10? +15? +20? +25? +30? +35? +40? +45? +50? 0.5 - 4.0 0.84 0.85 0.87 0.88 0.89 0.91 0.93 0.94 0.96 0.98 1.00 1.02 1.04 1.06 1.09 8.0 - 10 0.75 0.77 0.78 0.81 0.83 0.85 0.88 0.90 0.93 0.96 1.00 1.04 1.09 1.14 1.20 13 - 40 0.79 0.80 0.82 0.84 0.86 0.88 0.90 0.93 0.94 0.97 1.00 1.03 1.06 1.11 1.15 50-60 0.81 0.83 0.84 0.85 0.87 0.89 0.91 0.93 0.94 0.97 1.00 1.02 1.05 1.09 1.12 l002487a:03.08 ?2008 phoenix contact (multi-pole types: all poles symmetrically loaded)
thermal magnetic circuit breakers l002487a:03.08 phoenix contact ? p.o. box 4100 ? harrisburg, pa 17111-0100 phone: 800-888-7388 ? 717-944-1300 ? technical service: 800-322-3225 ? fax: 717-944-1625 e-mail: info@phoenixcon.com ? website: www.phoenixcontact.com ?2008 phoenix contact technical data auxiliary contact ratings voltage 240 v ac current 5 a contacts 1 form c rated wire sizes 2.5 mm?/ 14 awg weight 70 g contact functions auxiliary (h) or signal (s)* accessories * the tmc 6aux s/h can operate as either an auxiliary contact (h function) or a signal contact (s function). the operation of the auxiliary switch is determined at the time of installation. the signal contact (function s) status provides the automatic trip status of the protection device. the auxiliary (h function) provides the open/ closed status of the protective device. a test button on the front of the auxiliary switch simulates functions s or h. the test button also acts as a reset for the trip signal (function s) contacts. auxiliary contact lock out component 0902470 0902467 tmc 6aux s/h tmc 6lockout 3-phase comb bridge single row comb bridge 2809241 * 2809212 * 3-phase bridge/6 position single phase/3 position marking wire end covers 2809128 2818339 2809322 zbn 18:unbedruckt quantity: 10 pieces mpb f200x16/1gs length: 200 mm 3-phase bridge end cover * available in up to 57 positions